Netmate III

Overview
Climate Ⅲ/Netmate III mini series bring a high security monitor
Product Function

Support advantage encryption protocol such as HTTP, HTTPS, SSL, SSH, SNMPV1\V2c\V3;

Support telnet, supper terminal, WEB page configuration;

Compatible with multi-brand and multi-type of UPS;

Support to add on 20 pieces of Temp&Humid sensors via RS422/RS485 ports;

With 16 digital input terminals, support to add on dry contact type detectors;

With 5 digital output terminals, support to add on relay output control;

Support 8 analog input signal detect;

Support SNMP trap,E-mail alarm notification;

Support IPV4/IPV6;

Built-in optional GSM Modem, support SMS query or alarm notification;

Support scheduled task(regular self-testing, switch on/off);

Support history events and data record storage;

Comprehensive event handle( including event record and notification);

Comprehensive managing function( data logs, SNTP and task schedule);

Available to work with centralized software.

Ports Introduction
1-3. Led indicators
4. Ethernet port;
5. USB ports(connect USB add on device)
6. Reset(for factory default reset)
7. RS485 port(connect Temp&Humid sensor)
8. RS485
9. RS 232 port (connect UPS)
10. DC Input
11. Power indicator(it is on when power connect
Dimension
Technical Parameters
CPU32-bit ARM926EJ-S core 300 MHz high speed processor(CPU)
RAM64Mbyte SDRAMFlash ROM128M byte and Flash
Network Interface 10/100Mbps high speed Ethernet self adaptive
USB2 USB 2.0(connect USB add on device)
Serial Port1 RS232 serial port
1 RS485 serial port for expanding equipment
SNMP MIBSupport RFC1213, RFC1628, PPC MIB
Network ProtocolsTCP/IP, UDP, SNMP, Telnet, SNTP, HTTP, SMTP,DHCP,DNS,TFTP,ARP,ICMP,PPP
Encrypted ProtocolsHTTPS, SSH, SSL, IPV6, SNMP V3
LED IndicatorsPower, Status, Ready, LAN 10/100M Link/Active
Input(DC)8volt - 15voltRunning Temp:0-70℃
Power Consumption≤2.5WEnvironmentHumid:10 ~ 80%
Other ConfigurationsSystem clock for synchronizationSoftware UpgradeNetwork Upgrade
LanguageChinese, English and OEM other language
System SafetyProvided based on IP filtering mechanism, and system operation, control and management of the user ID and password protection
CertificatesCE/FCC
Monitoring Interface
Typical Application

Single/Three Phase UPS monitoring, Temperature Humidity Monitoring, Environmental System monitoring, etc

Accessories
SN
Name
M.N
Function
Connection
1
Temp&Humid Sensor
RC77015OLED Display
Detect data center indoor temperature and humidity parameters, every 20M² need install 1pc
RS422
RC77012Digital Type
NetmateII
Netmate II EXT
Batt Manager
NetmateLite
ArmModbusCard
Smart Power Socket
DrycontactCard
IPPOWER2012
MobileMate
MobileSite BE
SitePro
Netmate III