Netmate II EXT

Netmate II EXT is a Power & Environment monitoring host for small-size data center,
this product with compact and elegant design which collects RS232 protocol signal, dry contact
input signal and relay output signals, so users can monitor UPS via RS232 serial port,
at the same time extend environment monitoring easily.

Main Product Functions

  • Support web based monitoring for 1phase / 3phase UPS;
  • Monitor basic information such as current, voltage, bypass, utility power status, etc;
  • Multiple compatibility for different types and brands of UPS like APC, EMERSON, EATON, KELONG, KSTAR,etc.;
  • Support environment monitoring (temperature & humidity, smoke sensor, water leakage detection etc.);
  • Support e-mail and sound-light alarm;
  • Support web visit;
  • Support centralized monitoring.
> More Product Functions
  • Support SNMP V2 protocol, RFC1628 MIB, XPPC MIB;
  • Built-in WEB server to achieve HTTP access;
  • Multiple compatibility of various brands and types of UPS;
  • Support history events and data storage;
  • Support to extend 4 channels of dry contact signal input(Such as smoke, water leakage, door contact, etc);
  • Support 2 channels of relay manual control output and linkage control output;
  • Support to extend temperature and humidity detection and general air condition infrared control;
  • Support E-mail alarm and SNMP Trap;
  • Support multiple users authority management;
  • Support DHCP;
  • Support scheduled task;
  • Support TELNET, WEB page configurations;
  • Support network upgrade;
  • With SNTP synchronous clock.
∧ Put away

The application of topology

Interface

Ports Introduction

Screenshots

Dimension & Weight

Technical Parameter

Netmate II EXT
CPU32-bit ARM RISC-based 50 MHz CPU
Network Port10/100Mbps high-speed Ethernet self-adaptive
RAM16M byte SDRAMFlash ROM4M byte Flash
Serial Port2 RS232 high-speed asynchronous serial port;1 RS232 asynchronous serial port for UPS communication;1 for parameter configuration
1 RS422/485 port for extension of intelligent temperature and humidity detection module and air condition infrared control
Browser Support4 channels of photoelectric isolation dry contact input
2 channels of photoelectric isolation relay remote control output
Output ControlSupport Internet Explorer, Netscape or other compatible browser
SNMP MIBMIB-II(RFC1213, RFC1315, RFC1316), PPC MIB、RFC1628 MIB
Network ProtocolTCP/IP, UDP, SNMP, Telnet, SNTP, HTTP, SMTP, DHCP, DNS, TFTP, ARP,
ICMP, PPP, etc.
LED IndicatorPower, Status, Ready, LAN 10/100M Link/Active
Input Power (DC)8volt ~ 15voltPower Consumption≤5W
Running EnvironmentTemperature: 0°C ~ 70°COther ConfigurationReal-time system clock
Humidity: 10 ~ 85%
Multiple LanguagesChinese, English, also support OEM to other languages
Hardware Program UpdateNetwork upgradeSafety Certificate