SitemateII

Integrated UPS/Environment Monitoring System for Small Data Center
Overview
Sitemate II is specially developed and researched for small data center, it is based on IP network technology, supports UPS monitoring and environment system detection(temperature, humidity, smoke, leakage, motion, door contact, gas, etc) in one host. SitemateII provides fast interface visiting and user settings via web browser, once an abnormal alarm happens, it will rapidly give alarm notifications with email, SMS, sound light, etc, for a real sense to guarantee 7*24 hours unattended data center .
Product Function

Support advantage encryption protocol such as HTTP, HTTPS, SSL, SSH, SNMPV1\V2c\V3;

Support telnet, supper terminal, WEB page configuration;

Compatible with multi-brand and multi-type of UPS;

Support to add on 20 pieces of Temp&Humid sensors via RS422/RS485 ports;

With 16 digital input terminals, support to add on dry contact type detectors;

With 5 digital output terminals, support to add on relay output control;

Support 8 analog input signal detect;

Support SNMP trap,E-mail alarm notification;

Support IPV4/IPV6;

Built-in optional GSM Modem, support SMS query or alarm notification;

Support scheduled task(regular self-testing, switch on/off);

Support history events and data record storage;

Comprehensive event handle( including event record and notification);

Comprehensive managing function( data logs, SNTP and task schedule);

Available to work with centralized software.

Ports Introduction
14/17: RS422/RS485
(connect Temp&Humid sensor/general air condition infrared component).
15: Ethernet port
16: RS232 serial port
(connect UPS)
18: Digit output terminals
(connect relay output control)
19: Analog input terminals
20: Digit input terminals(connect dry contact type sensors)
Network Diagram
Dimension
Monitoring Interface
Technical Parameters
CPU32-bit ARM926EJ-S core 300 MHz high speed processor(CPU)
RAM64Mbyte SDRAMFlash ROM128M byte and Flash
Network Interface 10/100Mbps high speed Ethernet self adaptive
Device Ports
1 RS232 asynchronous serial port;
1 RS422/485 add on port
16 Digit input terminals (0-5V TTL level);
8 Analog input terminals (0 ~ 5V linear level);
5 Digit output terminals (12VDC / 1A).
Browser SupportInternet Explore, Netscape or compatible browsers.
SNMP MIBSupport MIBII (RFC1213, RFC1315, RFC1316)RFC1628, PPC MIB
Network ProtocolTCP/IP, UDP, SNMP, Telnet, SNTP, HTTP, SMTP, DHCP, DNS, TFTP, ARP, ICMP, PPP,etc.
LED IndicatorsPW, M-PW, RUN, DEV, PPP, IPP, WEBS, SNMP, EXT, MODEM, LAN 10/ 1 00M Link/Active
Input Power220-240V
Frequency50HzPower Consumption≤ 12W
Operating EnvironmentTemperature:0℃~70℃ Humidity:10~85%Software UpgradeNetwork upgrade
Other ConfigurationReal time system clock synchronization
LanguagesChinese/English, support OEM other languages.
System SecurityProvided filtering mechanism based on IP , and system operation, control
and management of the user ID and password protection.
Safety CertificateCE, FCC
Accessories
SN Name M.N Function Connection
1 Temp&Humid
Sensor
RC77015
OLED Display
Detect data center indoor temperature and humidity parameters,every 20M² need to install 1pc RS422
RC77012
Digital Type
2 AirCon Infrared
Component
RC77404 Remotely control air condition on-off,with auto reboot when AC recover RS422
3 Smoke Sensor RC77146 Detect indoor data center monitor status, every 20 M²-30M² need to install 1pc DI(terminals)
4 Infrared Sensor RC77147 Detect data center intrusion, motion status DI(terminals)
5 Door contact RC77424 Detect door or window on/off status DI(terminals)
6 Switching Value
Transmitter
RC77754 Detect on-off status of air condition/ new fan DI(terminals)
7 Sound Light
Sensor
RC77412 Give sound light alarm notification DI(terminals)
8 Dust Sensor / Detect dust capacity Analog
9 Flammable
Gas Sensor
/ Detect flammable gas Analog
10 Water Leakage
Sensor
RC77106
(Non-Locating)
Detect data center water leakage status, work with water leakage cable, cable (5/10/15/20/30meter)optional, support length custom DI(terminals)
NetmateII
Netmate II EXT
Batt Manager
NetmateLite
ArmModbusCard
Smart Power Socket
DrycontactCard
IPPOWER2012
MobileMate
MobileSite BE
SitePro
Netmate III
SitemateII